Oilfield Equipment Services.
 

 

Ajusta Pump.

OPERATING INSTRUCTIONS.

|Operating Instructions| |Stroke & Crank Arm Sizing Diagrams| | Stroke Sizing Formula
 |Stroke Length Adjustments | |Beam Balancing Instructions|  |Balancing Formula|
 |Anchoring Instructions| |BPD vs. Depth Curve|  |SPM to Stoke Ratios|  |Parts Listing|


BPD vs. Depth Curve & SPM to Stroke Length Ratios.


Oil Field Equipment Services

 

 

 

Oil Field Equipment Services

Inches

SPM

5 45.8
10 32.4
15 26.4
20 22.9
25 20.5
30 18.7


Caution! On DC applications many controllers are equipped with a variable speed control,  (VSC).  Before starting motor, confirm that the VSC is set for a slow setting.  Once motor is started, adjust VSC to achieve desired SPM.  Being careful not to exceed recommended SPM for the length of stroke you are using.

Back  Next